- Product number
- PA5-18465 - Provider product page
- Provider
- Invitrogen Antibodies
- Product name
- ERG Polyclonal Antibody
- Antibody type
- Polyclonal
- Antigen
- Synthetic peptide
- Description
- This antibody is predicted to react with mouse and rat based on sequence homology.
- Reactivity
- Human
- Host
- Goat
- Isotype
- IgG
- Vial size
- 100 µg
- Concentration
- 0.5 mg/mL
- Storage
- -20° C, Avoid Freeze/Thaw Cycles
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot was performed using Anti-ERG Polyclonal Antibody (Product # PA5-18465) and band of ~52 kDa corresponding to ERG was observed in Reh cell line and not in HT-29 and HCT 116 which are reported to be negative. An uncharacterized band (*) of ~110 kDa was also observed in Reh cell line. Modified whole cell extracts (1% SDS) (30 µg lysate) of Reh (Lane 1), HT- 29 (Lane 2) and HCT 116 (Lane 3) were electrophoresed using NuPAGE™ 10% Bis-Tris Protein Gel (Product # NP0302BOX). Resolved proteins were then transferred onto a nitrocellulose membrane (Product # IB23001) by iBlot® 2 Dry Blotting System (Product # IB21001). The blot was probed with the primary antibody (0.3 µg/mL) and detected by chemiluminescence with Rabbit anti-Goat IgG (H+L), Superclonal™ Recombinant Secondary Antibody, HRP (Product # A27014, 1:4000 dilution) using the iBright FL 1000 (Product # A32752). Chemiluminescent detection was performed using Novex® ECL Chemiluminescent Substrate Reagent Kit (Product # WP20005).
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Immunohistochemical staining of paraffin embedded of Human Prostate using Product # PA5-18465 at a concentration of 10 µg/mL. The tissue was processed by steamed antigen retrieval with citrate buffer pH 6 and stained with AP.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Immunohistochemical analysis of ERG in Human Prostate using a ERG monoclonal antibody (Product #PA5-18465) at 10 µg/mL. The Human Prostate tissue section was paraffin embeded and detected using steamed antigen retrieval with citrate buffer pH 6, AP-staining.
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Flow cytometric analysis of ERG in MCF7 cells using a polyclonal antibody (Product #PA5-18465). MCF7 cells (blue line) were paraformaldehyde fixed and permeabilized with 0.5% Triton. The primary antibody was incubated for one hour (10 µg/mL) followed by an Alexa Fluor 488 secondary antibody (1 µg/mL). IgG control: Unimmunized goat IgG (black line) followed by an Alexa Fluor 488 secondary antibody.