Antibody data
- Antibody Data
- Antigen structure
- References [0]
- Comments [0]
- Validations
- Western blot [1]
- Immunohistochemistry [1]
Submit
Validation data
Reference
Comment
Report error
- Product number
- PA5-51771 - Provider product page
- Provider
- Invitrogen Antibodies
- Product name
- AADAC Polyclonal Antibody
- Antibody type
- Polyclonal
- Antigen
- Recombinant full-length protein
- Description
- Immunogen sequence: PALQPLDVDL PSYQENSNFL FLSKSLMVRF WSEYFTTDRS LEKAMLSRQH VPVESSHLFK FINWSSLLPE RFIKGHVYNN PNYGSSELAK KYPGFLDVRA APLLADDNKL RGLPLTYVIT CQYDLLRDDG LMYVTRLRNT GV Highest antigen sequence identity to the following orthologs: Mouse - 73%, Rat - 69%.
- Reactivity
- Human
- Host
- Rabbit
- Isotype
- IgG
- Vial size
- 100 µL
- Concentration
- Lot-Specific
- Storage
- Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles.
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot was performed using Anti-AADAC Polyclonal Antibody (Product # PA5-51771) and a 45 kDa band corresponding to AADAC was observed in Hep G2, PC-3, DU 145 and HT-29 cell line and Mouse Liver but not in Mouse Ovary, Mouse Adipose, Mouse Skeletal Muscle, Mouse Lung and Mouse Brain. Fig. (a) Whole cell extracts (30 µg lysate) Hep G2 (Lane 1), PC-3 (Lane 2), DU 145 (Lane 3) and HT-29 (Lane 4); Fig. (b) Tissue extracts (30 µg lysate) of Mouse Liver (Lane 1), Mouse Ovary (Lane 2), Mouse Adipose (Lane 3), Mouse Skeletal Muscle (Lane 4), Mouse Lung (Lane 5) and Mouse Brain (Lane 6) were electrophoresed using Novex® NuPAGE® 4-12 % Bis-Tris gel (Product # NP0321BOX). Resolved proteins were then transferred onto a nitrocellulose membrane (Product # IB23001) by iBlot® 2 Dry Blotting System (Product # IB21001). The blot was probed with the primary antibody (1:500 dilution) and detected by chemiluminescence with Goat anti-Rabbit IgG (H+L), Superclonal™ Recombinant Secondary Antibody, HRP (Product # A27036, 1:4000 dilution) using the iBright FL 1000 (Product # A32752). Chemiluminescent detection was performed SuperSignal™ West Dura Extended Duration Substrate (Product # 34076).
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Immunohistochemical staining of AADAC in human duodenum tissue shows moderate positivity in glandular cells. Samples were probed using an AADAC Polyclonal Antibody (Product # PA5-51771).