500-P37G-100UG
antibody from Invitrogen Antibodies
Targeting: CCL7
FIC, MARC, MCP-3, MCP3, NC28, SCYA6, SCYA7
Antibody data
- Antibody Data
- Antigen structure
- References [1]
- Comments [0]
- Validations
- ELISA [1]
Submit
Validation data
Reference
Comment
Report error
- Product number
- 500-P37G-100UG - Provider product page
- Provider
- Invitrogen Antibodies
- Product name
- MCP-3 Polyclonal Antibody, PeproTech®
- Antibody type
- Polyclonal
- Antigen
- Recombinant full-length protein
- Description
- AA Sequence of recombinant protein: QPVGINTSTT CCYRFINKKI PKQRLESYRR TTSSHCPREA VIFKTKLDKE ICADPTQKWV QDFMKHLDKK TQTPKL. Preparation: Produced from sera of goats immunized with highly pure Recombinant Human MCP-3 (CCL7). Anti-Human MCP-3 (CCL7)-specific antibody was purified by affinity chromatography employing an immobilized Human MCP-3 (CCL7) matrix. Sandwich ELISA: To detect Human MCP-3 (CCL7) by sandwich ELISA (using 100 µL/well antibody solution) a concentration of 0.5-2.0 µg/mL of this antibody is required. This antigen affinity purified antibody, in conjunction with PeproTech Biotinylated Anti-Human MCP-3 (CCL7) (500-P37GBt) as a detection antibody, allows the detection of at least 0.2-0.4 ng/well of Recombinant Human MCP-3 (CCL7). Western Blot: To detect hMCP-3 by Western Blot analysis this antibody can be used at a concentration of 0.1- 0.2 µg/mL. Used in conjunction with compatible secondary reagents the detection limit for Recombinant hMCP-3 is 1.5-3.0 ng/lane, under either reducing or non-reducing conditions.
- Reactivity
- Human
- Host
- Goat
- Vial size
- 100 µg
- Concentration
- 0.1-1.0 mg/mL
- Storage
- -20°C
Submitted references Angiotensin II-induced mononuclear leukocyte interactions with arteriolar and venular endothelium are mediated by the release of different CC chemokines.
Mateo T, Abu Nabah YN, Abu Taha M, Mata M, Cerdá-Nicolás M, Proudfoot AE, Stahl RA, Issekutz AC, Cortijo J, Morcillo EJ, Jose PJ, Sanz MJ
Journal of immunology (Baltimore, Md. : 1950) 2006 May 1;176(9):5577-86
Journal of immunology (Baltimore, Md. : 1950) 2006 May 1;176(9):5577-86
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Sandwich ELISA: To detect Human MCP-3 (CCL7) by sandwich ELISA (using 100 µL/well antibody solution) a concentration of 0.5-2.0 µg/mL of MCP-3 Polyclonal Antibody (Product # 500-P37G-1MG) is required. This antigen affinity purified antibody, in conjunction with PeproTech MCP-3 Polyclonal Antibody, Biotin (Product # 500-P37GBT-1MG) as a detection antibody, allows the detection of at least 0.2-0.4 ng/well of Recombinant Human MCP-3 (CCL7).