Antibody data
- Antibody Data
- Antigen structure
- References [0]
- Comments [0]
- Validations
- Western blot [1]
- ELISA [1]
Submit
Validation data
Reference
Comment
Report error
- Product number
- 500-P245BT-1MG - Provider product page
- Provider
- Invitrogen Antibodies
- Product name
- Artemin Polyclonal Antibody, Biotin, PeproTech®
- Antibody type
- Polyclonal
- Antigen
- Recombinant full-length protein
- Description
- AA Sequence of recombinant protein: AGGPGSRARA AGARGCRLRS QLVPVRALGL GHRSDELVRF RFCSGSCRRA RSPHDLSLAS LLGAGALRPP PGSRPVSQPC CRPTRYEAVS FMDVNSTWRT VDRLSATACG CLG. Preparation: Produced from sera of rabbits immunized with highly pure Recombinant Human Artemin. Anti-Human Artemin-specific antibody was purified by affinity chromatography and then biotinylated. Sandwich ELISA: To detect hArtemin by sandwich ELISA (using 100 µL/well antibody solution) a concentration of 0.25-1.0 µg/mL of this antibody is required. This biotinylated polyclonal antibody, in conjunction with PeproTech Polyclonal Anti-Human Artemin (500-P245) as a capture antibody, allows the detection of at least 0.2-0.4 ng/well of Recombinant hArtemin. Western Blot: To detect hArtemin by Western Blot analysis this antibody can be used at a concentration of 0.1-0.2 µg/mL. Used in conjunction with compatible secondary reagents the detection limit for Recombinant hArtemin is 1.5-3.0 ng/lane, under either reducing or non-reducing conditions. 500-P245BT-1MG will be provided as 2 x 500 µg
- Reactivity
- Human
- Host
- Rabbit
- Conjugate
- Biotin
- Vial size
- 2 x 500 µg
- Concentration
- 0.1-1.0 mg/mL
- Storage
- -20°C
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western Blot: To detect hArtemin by Western Blot analysis Artemin Polyclonal Antibody, Biotin (Product # 500-P245BT-1MG) can be used at a concentration of 0.1-0.2 µg/mL. Used in conjunction with compatible secondary reagents the detection limit for Recombinant hArtemin is 1.5-3.0 ng/lane, under either reducing or non-reducing conditions.
- Conjugate
- Biotin
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Sandwich ELISA: To detect hArtemin by sandwich ELISA (using 100 µL/well antibody solution) a concentration of 0.25-1.0 µg/mL of Artemin Polyclonal Antibody, Biotin (Product # 500-P245BT-1MG) is required. This biotinylated polyclonal antibody, in conjunction with PeproTech Artemin Polyclonal Antibody (Product # 500-P245-1MG) as a capture antibody, allows the detection of at least 0.2-0.4 ng/well of Recombinant hArtemin.
- Conjugate
- Biotin