Antibody data
- Antibody Data
- Antigen structure
- References [0]
- Comments [0]
- Validations
- Western blot [5]
- Immunohistochemistry [2]
Submit
Validation data
Reference
Comment
Report error
- Product number
- PA5-27946 - Provider product page
- Provider
- Invitrogen Antibodies
- Product name
- CYP27A1 Polyclonal Antibody
- Antibody type
- Polyclonal
- Antigen
- Recombinant protein fragment
- Description
- Recommended positive controls: A549, mouse liver, rat liver. Predicted reactivity: Pig (83%), Rabbit (83%), Rhesus Monkey (98%). Store product as a concentrated solution. Centrifuge briefly prior to opening the vial.
- Reactivity
- Human, Mouse, Rat
- Host
- Rabbit
- Isotype
- IgG
- Vial size
- 100 µL
- Concentration
- 0.33 mg/mL
- Storage
- Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles.
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot analysis was performed on whole cell extracts (30 µg lysate) of A549 (Lane 1), DU-145 (Lane 2), PC-3 (Lane 3), LNCaP (Lane 4) and Caco-2 (Lane 5). The blot was probed with Anti-CYP27A1 Polyclonal Antibody (Product # PA5-27946, 1:1000 dilution) and detected by chemiluminescence using Goat anti Rabbit IgG (H+L) Superclonal™ Secondary Antibody, HRP conjugate (Product # A27036, 0.25 µg/ml, 1:4000 dilution). A 72 kDa band corresponding to CYP27A1 was detected across the cell lines tested and the protein expression was found to be low in LNCaP when compared to PC-3.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western Blot using CYP27A1 Polyclonal Antibody (Product # PA5-27946). Sample (30 µg of whole cell lysate). Lane A: A549. 7.5% SDS PAGE. CYP27A1 Polyclonal Antibody (Product # PA5-27946) diluted at 1:1,000. The HRP-conjugated anti-rabbit IgG antibody was used to detect the primary antibody.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- CYP27A1 Polyclonal Antibody detects CYP27A1 protein by western blot analysis. A. 50 µg rat liver lysate/extract.7.5% SDS-PAGE. CYP27A1 Polyclonal Antibody (Product # PA5-27946) dilution: 1:500. The HRP-conjugated anti-rabbit IgG antibody was used to detect the primary antibody.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western Blot using CYP27A1 Polyclonal Antibody (Product # PA5-27946). Sample (50 µg of whole cell lysate). Lane A: mouse Liver. 7.5% SDS PAGE. CYP27A1 Polyclonal Antibody (Product # PA5-27946) diluted at 1:1,000. The HRP-conjugated anti-rabbit IgG antibody was used to detect the primary antibody.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Knockdown of CYP27A1 was achieved by transfecting A549 cells with CYP27A1 specific siRNAs (Silencer® select Product # s3887, s3888). Western blot analysis (Fig. a) was performed using whole cell extracts from the CYP27A1 knockdown cells (lane 3), non-specific scrambled siRNA transfected cells (lane 2) and untransfected cells (lane 1). The blots were probed with CYP27A1 Polyclonal Antibody (Product # PA5-27946, 1:1000 dilution) and Goat anti-Rabbit IgG (H+L) Superclonal™ Secondary Antibody, HRP conjugate (Product # A27036, 0.25 µg/ml, 1:4000 dilution). Densitometric analysis of this western blot is shown in histogram (Fig. b). Decrease in signal upon siRNA mediated knock down confirms that antibody is specific to CYP27A1.
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- CYP27A1 Polyclonal Antibody detects CYP27A1 protein at cytoplasm in human endometrial carcinoma by immunohistochemical analysis. Sample: Paraffin-embedded human endometrial carcinoma. CYP27A1 Polyclonal Antibody (Product # PA5-27946) diluted at 1:500. Antigen Retrieval: Citrate buffer, pH 6.0, 15 min.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Immunohistochemical analysis of paraffin-embedded U87 xenograft, using CYP27A1 (Product # PA5-27946) antibody at 1:500 dilution. Antigen Retrieval: EDTA based buffer, pH 8.0, 15 min.