Antibody data
- Antibody Data
- Antigen structure
- References [3]
- Comments [0]
- Validations
- Western blot [4]
- Immunohistochemistry [1]
Submit
Validation data
Reference
Comment
Report error
- Product number
- MA1-26233 - Provider product page
- Provider
- Invitrogen Antibodies
- Product name
- Bcl-2 Monoclonal Antibody (124)
- Antibody type
- Monoclonal
- Antigen
- Synthetic peptide
- Description
- Positive control of Tonsil or human lung cell line suggested. This antibody works well with B5 or Bouin's fixed tissues. Formalin fixed tissues may give inconsistent results.
- Reactivity
- Human
- Host
- Mouse
- Isotype
- IgG
- Antibody clone number
- 124
- Vial size
- 250 µL
- Concentration
- Conc. Not Determined
- Storage
- 4° C, do not freeze
Submitted references Activation of P53 Via Nutlin-3a Reveals Role for P53 In ROS Signaling During Cardiac Differentiation of hiPSCs.
BCL2 and keratin 5 define the uterine-cervix-isthmus junction, a transition between endocervical and tubal-like epithelium.
Noxa up-regulation and Mcl-1 cleavage are associated to apoptosis induction by bortezomib in multiple myeloma.
Brandt EB, Li X, Nelson TJ
Journal of stem cell reports 2021;3(1)
Journal of stem cell reports 2021;3(1)
BCL2 and keratin 5 define the uterine-cervix-isthmus junction, a transition between endocervical and tubal-like epithelium.
Hoogduin KJ, Hopman AN, Ramaekers FC, McCluggage WG, Smedts F
International journal of gynecological pathology : official journal of the International Society of Gynecological Pathologists 2013 Jan;32(1):122-30
International journal of gynecological pathology : official journal of the International Society of Gynecological Pathologists 2013 Jan;32(1):122-30
Noxa up-regulation and Mcl-1 cleavage are associated to apoptosis induction by bortezomib in multiple myeloma.
Gomez-Bougie P, Wuillème-Toumi S, Ménoret E, Trichet V, Robillard N, Philippe M, Bataille R, Amiot M
Cancer research 2007 Jun 1;67(11):5418-24
Cancer research 2007 Jun 1;67(11):5418-24
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot analysis was performed on whole cell extracts (30 µg lysate) of MCF-7 (Lane 1), Raji (Lane 2), T-47D (Lane 3), MDA-MB-231 (Lane 4), HeLa (Lane 5) and Jurkat (Lane 6). The blot was probed with Anti-Bcl-2 Monoclonal Antibody (Product # MA1-26233, 1:500 dilution) and detected by chemiluminescence using Goat anti-Mouse IgG (H+L) Superclonal™ Secondary Antibody, HRP conjugate (Product # A28177, 0.25 µg/mL, 1:4000 dilution). A 27 kDa band corresponding to Bcl-2 was observed across the cell lines tested.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Knockdown of Bcl-2 was achieved by transfecting HeLa cells with Bcl-2 specific validated siRNAs (Silencer® select Product # s194310, s1915). Western blot analysis (Fig. a) was performed using whole cell extracts from the Bcl-2 knockdown cells (lane 3), non-specific scrambled siRNA transfected cells (lane 2) and untransfected cells (lane 1). The blots were probed with Bcl-2 Monoclonal Antibody (Product # MA1-26233, 1:500 dilution) and Goat anti-Mouse IgG (H+L) Superclonal™ Secondary Antibody, HRP conjugate (Product # A28177, 0.25 µg/mL, 1:4000 dilution). Densitometric analysis of this western blot is shown in histogram (Fig. b). Decrease in signal upon siRNA mediated knock down confirms that antibody is specific to Bcl-2.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot analysis of human lung cell. Extract with Bcl2, Bcl-2 Monoclonal Antibody (124) (Product # MA1-26233) Antibody.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Knockout of BCL2 was achieved by CRISPR-Cas9 genome editing using LentiArray™ Lentiviral sgRNA (Product # A32042, Assay ID CRISPR946648_LV) and LentiArray Cas9 Lentivirus (Product # A32064). Western blot analysis of BCL2 was performed by loading 30 µg of HeLa wild type (Lane 1), HeLa Cas9 (Lane 2) and Hela BCL2 KO (Lane 3) whole cell extracts. The samples were electrophoresed using NuPAGE™ Novex™ 4-12% Bis-Tris Protein Gel (Product # NP0321BOX). Resolved proteins were then transferred onto a nitrocellulose membrane (Product # IB23001) by iBlot® 2 Dry Blotting System (Product # IB21001). The blot was probed with Anti-Bcl-2 Monoclonal Antibody (124) (Product # MA1-26233, 1:500 dilution) and Goat anti-Mouse IgG (H+L) Superclonal™ Recombinant Secondary Antibody, HRP (Product # A28177, 1:4000 dilution) using the iBright FL 1000 (Product # A32752). Chemiluminescent detection was performed using Novex® ECL Chemiluminescent Substrate Reagent Kit (Product # WP20005). Loss of signal upon CRISPR mediated knockout (KO) using the LentiArray™ CRISPR product line confirms that antibody is specific to BCL2.
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Immunohistochemistry (Paraffin) analysis on paraffin embedded human tonsil stained with (Product # MA1-26233).