Antibody data
- Antibody Data
- Antigen structure
- References [1]
- Comments [0]
- Validations
- Western blot [1]
- Immunohistochemistry [1]
- Chromatin Immunoprecipitation [1]
- Other assay [1]
Submit
Validation data
Reference
Comment
Report error
- Product number
- PA5-47478 - Provider product page
- Provider
- Invitrogen Antibodies
- Product name
- GLI1 Polyclonal Antibody
- Antibody type
- Polyclonal
- Antigen
- Recombinant full-length protein
- Description
- In Western blots, approximately 5% cross-reactivity with recombinant human GLI-3 is observed. Reconstitute at 0.2 mg/mL in sterile PBS.
- Reactivity
- Human
- Host
- Goat
- Isotype
- IgG
- Vial size
- 100 µg
- Concentration
- 0.2 mg/mL
- Storage
- -20° C, Avoid Freeze/Thaw Cycles
Submitted references Forkhead box C2 promotes the invasion ability of human trophoblast cells through Hedgehog (Hh) signaling pathway.
Zhang Y, Zhang Y
Cell biology international 2018 Jul;42(7):859-866
Cell biology international 2018 Jul;42(7):859-866
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot analysis of GLI1 in HEK293 human embryonic kidney cell line transfected with human GLI-1. Samples were incubated in GLI1 polyclonal antibody (Product # PA5-47478) using a dilution of 1 µg/mL followed by a HRP-conjugated Anti-Goat IgG secondary antibody. A specific band was detected for GLI‚1 at approximately 165 kDa (as indicated). This experiment was conducted under reducing conditions.
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Immunohistochemical analysis of GLI1 in immersion fixed paraffin-embedded sections of human skin. Samples were incubated in GLI1 polyclonal antibody (Product # PA5-47478) using a dilution of 5 µg/mL overnight at 4 °C. Tissue was stained using the Anti-Goat HRP-DAB Cell & Tissue Staining Kit (brown) and counterstained with hematoxylin (blue).
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- ChIP assay of GLI1 in Jurkat human acute T cell leukemia cell line treated with 50 ng/mL PMA and 200 ng/mL calcium ionomycin. Samples were immunoprecipitated with GLI1 polyclonal antibody (Product # PA5-47478) for 15 minutes in an ultrasonic bath using a dilution of 5 μg followed by a Biotinylated Anti-Goat IgG secondary antibody. Cell line was treated with 50 ng/mL PMA and 200 ng/mL calcium ionomycin for 30 minutes were fixed using formaldehyde, resuspended in lysis buffer, and sonicated to shear chromatin. Immunocomplexes were captured using 50 μL of MagCellect Streptavidin Ferrofluid and DNA was purified using chelating resin solution. The Bcl-2 promoter was detected by standard PCR.
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- NULL