Antibody data
- Antibody Data
- Antigen structure
- References [5]
- Comments [0]
- Validations
- Western blot [1]
Submit
Validation data
Reference
Comment
Report error
- Product number
- A01246-2 - Provider product page
- Provider
- Boster Biological Technology
- Product name
- Anti-Occludin/OCLN Antibody Picoband™
- Antibody type
- Polyclonal
- Description
- Rabbit IgG polyclonal antibody for Occludin/OCLN detection. Tested with WB, IHC-P, ICC/IF, FCM, Direct ELISA in Human.
- Reactivity
- Human
- Host
- Rabbit
- Vial size
- 100μg/vial
- Concentration
- Add 0.2ml of distilled water will yield a concentration of 500ug/ml.
- Storage
- At -20°C for one year. After reconstitution, at 4°C for one month. It can also be aliquoted and stored frozen at -20°C for a longer time. Avoid repeated freezing and thawing.
- Handling
- Add 0.2ml of distilled water will yield a concentration of 500ug/ml.
Submitted references Danggui-Shaoyao-San Attenuates Cognitive Impairment via the Microbiota-Gut-Brain Axis With Regulation of Lipid Metabolism in Scopolamine-Induced Amnesia.
Prevotellaceae produces butyrate to alleviate PD-1/PD-L1 inhibitor-related cardiotoxicity via PPARα-CYP4X1 axis in colonic macrophages.
Kaempferol alleviates acute alcoholic liver injury in mice by regulating intestinal tight junction proteins and butyrate receptors and transporters.
Intranasal administration of human umbilical cord mesenchymal stem cells-conditioned medium enhances vascular remodeling after stroke.
Age-related changes in small intestinal mucosa epithelium architecture and epithelial tight junction in rat models.
Liu P, Zhou X, Zhang H, Wang R, Wu X, Jian W, Li W, Yuan D, Wang Q, Zhao W
Frontiers in immunology 2022;13:796542
Frontiers in immunology 2022;13:796542
Prevotellaceae produces butyrate to alleviate PD-1/PD-L1 inhibitor-related cardiotoxicity via PPARα-CYP4X1 axis in colonic macrophages.
Chen Y, Liu Y, Wang Y, Chen X, Wang C, Chen X, Yuan X, Liu L, Yang J, Zhou X
Journal of experimental & clinical cancer research : CR 2022 Jan 3;41(1):1
Journal of experimental & clinical cancer research : CR 2022 Jan 3;41(1):1
Kaempferol alleviates acute alcoholic liver injury in mice by regulating intestinal tight junction proteins and butyrate receptors and transporters.
Chen J, Xuan YH, Luo MX, Ni XG, Ling LQ, Hu SJ, Chen JQ, Xu JY, Jiang LY, Si WZ, Xu L, Gao H, Liu Z, Li H
Toxicology 2020 Jan 15;429:152338
Toxicology 2020 Jan 15;429:152338
Intranasal administration of human umbilical cord mesenchymal stem cells-conditioned medium enhances vascular remodeling after stroke.
Zhao Q, Hu J, Xiang J, Gu Y, Jin P, Hua F, Zhang Z, Liu Y, Zan K, Zhang Z, Zu J, Yang X, Shi H, Zhu J, Xu Y, Cui G, Ye X
Brain research 2015 Oct 22;1624:489-496
Brain research 2015 Oct 22;1624:489-496
Age-related changes in small intestinal mucosa epithelium architecture and epithelial tight junction in rat models.
Ren WY, Wu KF, Li X, Luo M, Liu HC, Zhang SC, Hu Y
Aging clinical and experimental research 2014 Apr;26(2):183-91
Aging clinical and experimental research 2014 Apr;26(2):183-91
No comments: Submit comment
Supportive validation
- Submitted by
- Boster Biological Technology (provider)
- Main image
- Experimental details
- Western blot analysis of Occludin/OCLN using anti-Occludin/OCLN antibody (A01246-2). Electrophoresis was performed on a 5-20% SDS-PAGE gel at 70V (Stacking gel) / 90V (Resolving gel) for 2-3 hours. The sample well of each lane was loaded with 50ug of sample under reducing conditions. Lane 1: human HepG2 whole cell lysates, Lane 2: human HEK293 whole cell lysates. After Electrophoresis, proteins were transferred to a Nitrocellulose membrane at 150mA for 50-90 minutes. Blocked the membrane with 5% Non-fat Milk/ TBS for 1.5 hour at RT. The membrane was incubated with rabbit anti-Occludin/OCLN antigen affinity purified polyclonal antibody (Catalog # A01246-2) at 0.5 μg/mL overnight at 4°C, then washed with TBS-0.1%Tween 3 times with 5 minutes each and probed with a goat anti-rabbit IgG-HRP secondary antibody at a dilution of 1:10000 for 1.5 hour at RT. The signal is developed using an Enhanced Chemiluminescent detection (ECL) kit (Catalog # EK1002) with Tanon 5200 system. A specific band was detected for Occludin/OCLN at approximately 65KD. The expected band size for Occludin/OCLN is at 59KD.
- Additional image