Antibody data
- Antibody Data
- Antigen structure
- References [1]
- Comments [0]
- Validations
- Western blot [3]
- Immunohistochemistry [1]
Submit
Validation data
Reference
Comment
Report error
- Product number
- PA5-27272 - Provider product page
- Provider
- Invitrogen Antibodies
- Product name
- CD51 Polyclonal Antibody
- Antibody type
- Polyclonal
- Antigen
- Recombinant protein fragment
- Description
- Recommended positive controls: RD (Rhabdomyosarcoma) cell (Mock control), RD transfected scramble siRNA, HUVEC. Predicted reactivity: Mouse (88%), Pig (92%), Sheep (90%), Rhesus Monkey (99%), Bovine (91%). Store product as a concentrated solution. Centrifuge briefly prior to opening the vial.
- Reactivity
- Human, Mouse
- Host
- Rabbit
- Isotype
- IgG
- Vial size
- 100 µL
- Concentration
- 0.58 mg/mL
- Storage
- Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles.
Submitted references Tracking Radiolabeled Endothelial Microvesicles Predicts Their Therapeutic Efficacy: A Proof-of-Concept Study in Peripheral Ischemia Mouse Model Using SPECT/CT Imaging.
Giraud R, Moyon A, Simoncini S, Duchez AC, Nail V, Chareyre C, Bouhlel A, Balasse L, Fernandez S, Vallier L, Hache G, Sabatier F, Dignat-George F, Lacroix R, Guillet B, Garrigue P
Pharmaceutics 2022 Jan 4;14(1)
Pharmaceutics 2022 Jan 4;14(1)
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western Blot analysis of CD51 was performed by separating 30 µg of A549 whole cell and membrane extracts by 7.5% SDS-PAGE. Proteins were transferred to a membrane and probed with a CD51 Polyclonal Antibody (Product # PA5-27272) at a dilution of 1:500 and a HRP-conjugated anti-rabbit IgG secondary antibody.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western Blot using CD51 Polyclonal Antibody (Product # PA5-27272). Sample (30 µg of whole cell lysate). Lane A: HUVEC. 7.5% SDS PAGE. CD51 Polyclonal Antibody (Product # PA5-27272) diluted at 1:500. The HRP-conjugated anti-rabbit IgG antibody was used to detect the primary antibody.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western Blot using CD51 Polyclonal Antibody (Product # PA5-27272). Sample (30 µg of whole cell lysate). Lane A: RD (Rhabdomyosarcoma) cell (Mock control). Lane B: RD transfected scramble siRNA. Lane C: RD transfected ITGAV siRNA.8% SDS PAGE. CD51 Polyclonal Antibody (Product # PA5-27272) diluted at 1:900. The HRP-conjugated anti-rabbit IgG antibody was used to detect the primary antibody.
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Immunohistochemical analysis of paraffin-embedded human colon carcinoma, using Integrin alpha V (Product # PA5-27272) antibody at 1:250 dilution. Antigen Retrieval: EDTA based buffer, pH 8.0, 15 min.