Antibody data
- Antibody Data
- Antigen structure
- References [0]
- Comments [0]
- Validations
- Western blot [4]
- Immunohistochemistry [1]
Submit
Validation data
Reference
Comment
Report error
- Product number
- PA1-9069 - Provider product page
- Provider
- Invitrogen Antibodies
- Product name
- MMP7 Polyclonal Antibody
- Antibody type
- Polyclonal
- Antigen
- Synthetic peptide
- Reactivity
- Human
- Host
- Goat
- Isotype
- IgG
- Vial size
- 100 µg
- Concentration
- 0.5 mg/mL
- Storage
- -20° C, Avoid Freeze/Thaw Cycles
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot detection of MMP7 in human breast lysate using Product # PA1-9069.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot detection of MMP7 in human breast lysate using Product # PA1-9069.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot detection of MMP7 in human breast lysate using Product # PA1-9069.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot was performed using Anti-MMP7 Polyclonal Antibody (Product # PA1-9069) and a 27 kDa band corresponding to MMP7 was observed. Whole cell extracts (30 µg lysate) of HT-29 (Lane 1), HT-29 treated with Protein Transport Inhibitor (PTI) cocktail (1X, 4 hours), SK-BR-3 (Lane 3) and SK-BR-3 treated with Protein Transport Inhibitor (PTI) cocktail (1X, 4 hours) (Lane 4) were electrophoresed using NuPAGE™ 10% Bis-Tris Protein Gel (Product # NP0301BOX). Resolved proteins were then transferred onto a Nitrocellulose membrane (Product # IB23001) by iBlot® 2 Dry Blotting System (Product # IB21001). The blot was probed with the primary antibody (0.03 µg/mL) and detected by chemiluminescence with Rabbit anti-Goat IgG (H+L) Superclonal™ Recombinant Secondary Antibody, HRP (Product # A27014,1:4000) using the iBright FL 1000 (Product # A32752). Chemiluminescent detection was performed using Novex® ECL Chemiluminescent Substrate Reagent Kit (Product # WP20005). Relative expression was observed between HT-29 and SK-BR-3, a cell line which is reported to express MMP7 at very low levels.
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Immunohistochemical analysis of MMP7 in paraffin embedded human uterus using a MMP7 polyclonal antibody (Product #PA1-9069) at a concentration of 3.8 µg/mL. Steamed antigen retrieval was performed with pH 6 buffered citrate. Samples were then stained with alkaline phosphatase.