Antibody data
- Antibody Data
- Antigen structure
- References [0]
- Comments [0]
- Validations
- Flow cytometry [2]
Submit
Validation data
Reference
Comment
Report error
- Product number
- H063T03R02-A - Provider product page

- Provider
- Invitrogen Antibodies
- Product name
- CD23 Monoclonal Antibody (EBVCS2), NovaFluor™ Red 685, eBioscience™
- Antibody type
- Monoclonal
- Antigen
- Other
- Description
- Description<br>The EBVCS2 monoclonal antibody reacts with human CD23, a 45 kDa type II transmembrane glycoprotein.<br><br>This product contains 1 vial of NovaFluor conjugate and 1 vial of CellBlox Plus Blocking Buffer.<br><br>Applications Tested<br>This EBVCS2 antibody has been pre-diluted and tested by flow cytometric analysis of normal human peripheral blood cells. This may be used at 5 µL (0.2 µg) per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test.<br><br>Master mixes<br>• Master mixes of NFs should be made at 2-8 °C and may be made up to 4 hours ahead of time.<br>• We do not recommend storing master mixes containing NovaFluor conjugates overnight or longer.<br><br>Whole Blood compatibility<br>• When utilizing whole blood (as opposed to density-gradient-purified PBMC), we recommend lysing red blood cells in bulk prior to staining with NovaFluor conjugates.<br>• See the Bulk Lysis of Human Whole Blood protocol <a href="https://www.thermofisher.com/us/en/home/references/protocols/cell-and-tissue-analysis/protocols/red-blood-cell-lysis.html">here</a>.<br>• Staining of whole blood with NovaFluor conjugates followed by lysis of red blood cells may result in higher-than-expected background staining.<br><br>Viability dye compatibility<br>• NovaFluor dyes are not compatible with DNA intercalating viability dyes.<br>• Do not use viability dyes such as propidium iodide, 7-actinomycin D (7-AAD) and DAPI. <a href="https://www.thermofisher.com/us/en/home/life-science/cell-analysis/flow-cytometry/flow-cytometry-assays-reagents/cell-viability-assays-flow-cytometry/fixable-viability-dyes-flow-cytometry.html">Invitrogen LIVE/DEAD Fixable Dead Cell stains</a> are recommended for use with NovaFluor dyes.<br><br>CellBlox Plus Blocking Buffer<br>• This NovaFluor conjugate comes with CellBlox Plus Blocking Buffer (Cat. No. C001T03F01), essential for optimal staining.<br>• Use CellBlox Plus Blocking Buffer in all experiments with NovaFluor conjugates.<br>• Add 5 µL per sample to antibody cocktails/master mixes (regardless of how many Novafluor-conjugated antibodies are present) before combining with cells.<br>• CellBlox Plus Blocking Buffer is compatible with either Super Bright Complete Blocking Buffer or Brilliant Stain Buffer and can be used in antibody cocktails/master mixes with those reagents.<br>• For single-color controls, use 5 µL of CellBlox Plus Blocking Buffer per 100 µL of cell sample (10^3 to 10^8 cells).<br><br>NovaFluor conjugates are based on Phiton technology utilizing novel fluorophore-containing nucleic acid dye structures that allow for engineered fluorescent signatures with consideration for spillover and spread impacts. <a href="https://www.thermofisher.com/us/en/home/life-science/cell-analysis/flow-cytometry/antibodies-for-flow-cytometry/novafluor-dyes.html">Learn more</a><br><br>Excitation: 637 nm; Emission: 685 nm; Laser: 633-640 nm (Red) Laser
- Reactivity
- Human
- Host
- Mouse
- Isotype
- IgG
- Antibody clone number
- EBVCS2
- Vial size
- 100 Tests
- Concentration
- 0.2 μg/Test
- Storage
- 4°C, store in dark, DO NOT FREEZE!
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image

- Experimental details
- Normal human peripheral blood cells were unstained (left) or stained with CD23 Monoclonal Antibody, NovaFluor Red 685 (right). All cells were co-stained with CD19 Monoclonal Antibody, eFluor 450 (Product # 48-0199-42). Total viable cells in the lymphocyte gate were used for analysis, as determined by LIVE/DEAD Blue (Product # L34962). Data was acquired on a 5-laser Cytek Aurora and unmixed with autofluorescence extraction.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image

- Experimental details
- Spectral signature for NovaFluor Red 685 collected on a 5-laser Cytek Aurora Full Spectrum flow cytometer using Cytek assay settings. Human peripheral blood mononuclear cells were stained with anti-human CD4 (SK3) and signatures displayed following gating on the lymphocyte population.