PA1-28393
antibody from Invitrogen Antibodies
Targeting: SOCS2
CIS2, Cish2, SOCS-2, SSI-2, SSI2, STATI2
Antibody data
- Antibody Data
- Antigen structure
- References [0]
- Comments [0]
- Validations
- Western blot [2]
- Immunohistochemistry [1]
Submit
Validation data
Reference
Comment
Report error
- Product number
- PA1-28393 - Provider product page
- Provider
- Invitrogen Antibodies
- Product name
- Anti-SOCS2 Polyclonal Antibody
- Antibody type
- Polyclonal
- Antigen
- Synthetic peptide
- Description
- PA1-28393 detects SOCS2 from mouse, rat, human samples. PA1-28393 has been successfully used in immunoprecipitation, Western blot applications. The PA1-28393 immunogen is: Synthetic peptide (PTRLKDYLEEYKFQV) correspondingto amino acids 184-198 of human, rat and mouse SOCS 2. Store product as a concentrated solution. Centrifuge briefly prior to opening the vial. For short-term storage (1-2 weeks), product can be stored at 4°C. For long-term storage, aliquot and store product at -20° C or below, avioiding multiple freeze-thaw cycles.
- Reactivity
- Human, Mouse, Rat
- Host
- Rabbit
- Isotype
- IgG
- Vial size
- 50 µg
- Concentration
- 0.2 mg/mL
- Storage
- Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles.
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot analysis of SOCS2 in mouse spleen tissue cell lysate using a SOCS2 polyclonal antibody (Product # PA1-28393) at a dilution of 2 µg/mL.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot analysis was performed on whole cell extracts (30 µg lysate) of HeLa (Lane 1), A549 (Lane 2), HT-29 (Lane 3), HCT 116 (Lane 4), MCF7 (Lane 5), A-431 (Lane 6), NIH/3T3 (Lane 7) and HT-1080 (Lane 8). The blot was probed with Anti-SOCS2 Polyclonal Antibody (Product # PA1-28393, 1 µg/ml) and detected by chemiluminescence using Goat anti-Rabbit IgG (H+L) Superclonal™ Secondary Antibody, HRP conjugate (Product # A27036, 0.25 µg/ml, 1:4000 dilution). A 22 kDa band corresponding to SOCS2 was observed across the cell lines tested.
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Immunohistochemical analysis of SOCS2 in cardiac myocytes using a SOCS2 polyclonal antibody (Product # PA1-28393). The image shows localization of the antibody as the precipitated red signal, with a hematoxylin purple nuclear counterstain in cardiac myocytes of the heart.