Antibody data
- Antibody Data
- Antigen structure
- References [0]
- Comments [0]
- Validations
- Immunohistochemistry [2]
- Flow cytometry [1]
- Protein array [1]
- Other assay [1]
Submit
Validation data
Reference
Comment
Report error
- Product number
- V8224 - Provider product page
- Provider
- NSJ Bioreagents
- Product name
- CD19 Antibody / B-lymphocyte marker
- Antibody type
- Monoclonal
- Description
- Protein G affinity chromatography
- Reactivity
- Human
- Host
- Mouse
- Conjugate
- Unconjugated
- Antibody clone number
- CD19/3116
- Vial size
- 20 µg, 100 µg (with BSA, sodium azide), 100 µg (without BSA, sodium azide)
- Concentration
- 0.2 mg/ml, 1 mg/ml
- Storage
- Store the CD19 antibody at 2-8oC (with azide) or aliquot and store at -20oC or colder (without azide).
No comments: Submit comment
Supportive validation
- Submitted by
- NSJ Bioreagents (provider)
- Main image
- Experimental details
- IHC staining of FFPE human tonsil with CD19 antibody (clone CD19/3116). HIER: boil tissue sections in pH 9 10mM Tris with 1mM EDTA for 10-20 min and allow to cool before testing.
- Submitted by
- NSJ Bioreagents (provider)
- Main image
- Experimental details
- IHC staining of FFPE human tonsil with CD19 antibody (clone CD19/3116). HIER: boil tissue sections in pH 9 10mM Tris with 1mM EDTA for 10-20 min and allow to cool before testing.
Supportive validation
- Submitted by
- NSJ Bioreagents (provider)
- Main image
- Experimental details
- Flow cytometry testing of human Raji cells with CD19 antibody (clone CD19/3116); Red=isotype control, Blue= CD19 antibody.
Supportive validation
- Submitted by
- NSJ Bioreagents (provider)
- Main image
- Experimental details
- Analysis of HuProt(TM) microarray containing more than 19,000 full-length human proteins using CD19 antibody (clone CD19/3116). These results demonstrate the foremost specificity of the CD19/3116 mAb.Z- and S- score: The Z-score represents the strength of a signal that an antibody (in combination with a fluorescently-tagged anti-IgG secondary Ab) produces when binding to a particular protein on the HuProt(TM) array. Z-scores are described in units of standard deviations (SD's) above the mean value of all signals generated on that array. If the targets on the HuProt(TM) are arranged in descending order of the Z-score, the S-score is the difference (also in units of SD's) between the Z-scores. The S-score therefore represents the relative target specificity of an Ab to its intended target.
Supportive validation
- Submitted by
- NSJ Bioreagents (provider)
- Main image
- Experimental details
- SDS-PAGE analysis of purified, BSA-free CD19 antibody (clone CD19/3116) as confirmation of integrity and purity.